  • Boss . commented,

     For analog design which is my main area of work I rarely use the autorouter, as layout and the track routes are important elements of the design. But if you use the autorouter use it in steps and ...

  • Boss . commented,

    Check these out https://uk.rs-online.com/web/p/iec-filters/7823970/ I think they are an IEC C8 connector that the C7 (confusing!) plugs into. This will provide a range to select fromhttps://uk.rs-o...

  • Boss . commented,

    SW1 is wrong, when not connecting to the relay it will power the Tens unit continuously, just remove the link between the two poles or use the single pole switch I drew earlier.Unless my sums scrib...

  • Boss . commented,

    The switch is in my edited diagram of yours posted above. Just a switch in series with the Tens power unit. If you do not have a switch the Tens will be powered all of the time when not generating ...

  • Boss . commented,

    Yes, but do consider the start up and ending situations, you may require a disable switch? and if not built in a diode across the coil. You could also add the bridge rectifier into the circuit so ...

  • Boss . commented,

    On my system it is as below, but the PCB window must be active.  

  • Boss . commented,

    Well, that confirms it is 120V DC.... I suggest you examine relays in the 110V to 120V operating range.Non-Latching Relays | RS Components (rs-online.com) select some options on coil voltage then s...

  • Boss . commented,

    A Happy New Year to you. With the PCB view active, go to the menubar and select 3D - 3D view.

  • Boss . commented,

    Hmmm, well from how you describe your customers' knowledge I would first question the 120VDC output from the generator, are you sure it's not 12.0VDC? 0V is both precise and vague, in the sense are...

  • Boss . commented,

    Hi Richard, I kept my original reply brief to try get more info from you.Based on your circuit above the issues requiring to resolve are: Relays as Brad says have very wide ranges of operation whic...